Running Cost

Heat pump vs existing — running cost

An indicative annual running-cost comparison using the MCS 031 efficiency basis: the heat pump SPF for space heating and the fixed factor for hot water, against the customer's existing system at today's prices.

⚠️ Indicative comparison — not the formal MCS 031 pre-sale performance estimate. The official estimate must be produced via the proper EPC-data method and presented in the MCS format. Enter current prices and the SPF from the MCS 031 heat emitter guide for accurate results.
1 Annual heat demand

Take these from the property's EPC (estimated annual energy for heating & hot water) or your heat loss / design figures.

2 Heat pump & electricity

SPF from the MCS 031 heat emitter guide for the property's heat loss (W/m²) and design flow temperature — e.g. around 3.1 at 50°C flow. The hot water factor is fixed at 1.7 in MCS 031. For the electricity rate, a dedicated heat pump tariff changes the comparison significantly.

3 Existing system

Efficiency: a modern condensing gas boiler is around 0.90, oil ~0.85, direct electric 1.0. For oil/LPG, enter the effective cost per kWh (litre price ÷ kWh per litre). Use the customer's current unit rate.

Indicative only. This is a running-cost comparison to support the customer conversation, not the regulated MCS 031 pre-sale performance estimate, which must be produced through the proper EPC-data method and presentation. Energy prices change frequently — always enter current rates. SPF must come from the MCS 031 heat emitter guide for the specific property.

Autosaves to this device.